To meet the requirement of continuous reactive power compensation with low cost, high reliability and large capacity, a hybrid Active Power Factor Correction was proposed based on TSC (thyristor switched capacitor in parallel) and SVG (static var compensator). This system consisting of discrete subsystem TSC and continuous subsystem SVG, coordinated the capacitor switching rating of TSC with dynamic compensation of SVG by using two hybrid control laws based on expert decision making, made full use of their respective advantages. The machine learning approach was applied to avoid repeated movements of capacitors and extend equipment life.
Elcosine Power-HPFC SVG Hybrid Active Power Factor Correction
Elcosine Power-HPFC Hybrid Active Power Factor Correction adopts the configuration scheme of combining Elcosine Power-ASVG Advanced Static var Generator and switching capacitor/reactor, and implements different reactive compensation schemes according to the actual needs of users on site, so as to achieve the best combination of price and effect.
Elcosine Power-HPFC Hybrid Active Power Factor Correction device consists of two parts: Static Var Generator and switching capacitor / reactor reactive compensation unit. In Elcosine Power-HPFC hybrid dynamic reactive power compensation device, each unit is designed and produced in the method of low power, small volume and low cost, and both of them are optional, and can be combined in the best and flexible way according to the actual reactive state of the site, so as to achieve the optimum ratio of operation effect and cost.
A united system of thyristor switched capacitor (TSC) and Elcosine Power-SVG static var generator was proposed to improve voltage regulation, stability, and power factor in ac transmission and distribution systems. The TSC is consisted of multi-groups binary-coded capacitors, which is mainly used for large capacity var compensation step by step. Elcosine Power-SVG compensates small capacity reactive power continuously, and filters harmonics generated by the nonlinear load.
When Elcosine Power-SVG compensates harmonics with traditional control method, it may run into oscillation if the Elcosine Power-SVG controller does not consider the interaction between TSC and Elcosine Power-SVG, so a selective harmonic compensation method is present to solve the problem. A predictive control algorithm for TSC is studied to have a correct compensation when the load changes rapidly. The proposed united compensation system can implement continuous reactive power and harmonic currents compensation cost-effectively.
Modular Design
Elcosine Power Static Var Generator has a advanced modular design. Usually Elcosine Power-SVG consists of one or severalVG S modules and an optional touched LCD Human Machine Interface. Each SVG module is an independent harmonic filtering system, and users can change the harmonic filtering system rating by adding or removing SVG modules.
According to the mounting type, Elcosine Power-SVG can be divided into Rack Modular SVG,Wall-mounted SVG and free landing SVG.
Model Description
Elcosine Power-HPFC hybrid Active Power Factor Correction series cover from 100kVAr to 500kVAr per cabinet, support SVG control thyristor switched capacitors(Or Contactor switched type).
| SN | Item | Rated Capacity | Factory Model | Dimensions
(W*D*H,MM) |
N.W (KG) |
Packing Size (W*D*H,MM) |
G.W (KG) |
| 1 | HPFC | 100kVAr | Elcosine Power-HPFC/100-4-4L-50k | 800*1000*2200 | 300 | 990*1140*2455 | 340 |
| 2 | HPFC | 150kVAr | Elcosine Power-HPFC/150-4-4L-50k | 800*1000*2200 | 320 | 990*1140*2455 | 360 |
| 3 | HPFC | 200kVAr | Elcosine Power-HPFC/200-4-4L-50k | 800*1000*2200 | 340 | 990*1140*2455 | 380 |
| 4 | HPFC | 250kVAr | Elcosine Power-HPFC/250-4-4L-50k | 800*1000*2200 | 360 | 990*1140*2455 | 400 |
| 5 | HPFC | 300kVAr | Elcosine Power-HPFC/300-4-4L-100k | 800*1000*2200 | 380 | 990*1140*2455 | 420 |
| 6 | HPFC | 350kVAr | Elcosine Power-HPFC/350-4-4L-100k | 800*1000*2200 | 380 | 990*1140*2455 | 440 |
| 7 | HPFC | 400kVAr | Elcosine Power-HPFC/400-4-4L-100k | 800*1000*2200 | 400 | 990*1140*2455 | 460 |
| 8 | HPFC | 450kVAr | Elcosine Power-HPFC/450-4-4L-100k | 800*1000*2200 | 400 | 990*1140*2455 | 480 |
| 9 | HPFC | 500kVAr | Elcosine Power-HPFC/500-4-4L-100k | 1000*800*2200 | 420 | 990*1140*2455 | 500 |