Elcosine Energia based on 3-level topology, is an Active Harmonic Filter (AHF) system designed to eliminate harmonic oscillations and reduce costs consequently. AHF is a versatile solution, easily tailored to deliver power factor improvement, voltage variation control, flicker mitigation and load balancing functionality, and highly improved power quality in networks while reducing harmonic pollution.

  • Item NO.: Elcosine Energia
  • Order(MOQ): 1
  • Payment: T/T,LC
  • Market Price: $1500
  • Product Origin: Made in India
  • Lead Time: 7 days
  • Weight: 50kg

ELC700 series reactive power automatic compensation controller is suitable for automatic adjustment of capacitor compensation device of low voltage power distribution system, so that the power factor can reach the user’s predetermined state, increase the utilization power of power transformers, reduce line losses, and improve the voltage quality of power supply.

Standard: JB/T 9663-2013

Features

  • Calculate the switching capacitor capacity based on the fundamental reactive power, which can avoid any form of switching vibration
  • Correctly display the power factor of the power grid in the harmonic place
  • High power factor Measurement accuracy and wide display range
  • Real-time display total power factor (PF) and fundamental power factor (DPF)
  • Real-time display THDv and THDi
  • There are 12 output methods for users to choose
  • HMI easy to operate
  • Various control parameters are fully digital adjustable and intuitive to use
  • With two working modes: automatic operation and manual operation
  • With over-voltage and under-voltage protection
  • With voltage harmonic protection function
  • With data storage protection when power off
  • Low current signal input impedance

Model and Meaning

No.NameMeaning
1Reactive power compensation controllerELC
2Physical termsF=G+W G: power factor W: reactive power
3Mixed compensation3: mixed compensation; no mark: three phase compensation
4With communication functionC: with communication function; no mark: without communication function
5Output stepsoptional step: 4、6、8、10、12、16
6OutputJ: static output D: dynamic output
RPCF-16Three phase compensation (RPCF-16J equipped with AC contactor, RPCF-16D equipped with composite switch or contactless switch)
RPCF3-16mixed compensation (RPCF3-16J equipped with AC contactor, RPCF3-16D equipped with composite switch or contactless switch)
Normal working and installation conditions
Ambient temperature-25°C ~ +55°C
Relative humidityRelative humidity ≤50% at 40°C ; ≤90% at 20°C
Altitude≤2500m
Environmental conditionsno harmful gas and steam, no conductive or explosive dust, no severe mechanical vibration
Power condition 
Rated voltageAC 220V/380V
Rated working currentAC 0~5A
Rated frequency45Hz~65Hz
  

Technical Parameters

Performance

Control step4, 6, 8, 10, 12, 16
Measure reactive power0-9999 kvar
Sensitivity60mA
Static Output contact capacityAC 220V 7A
dynamic Output contact capacity12V/10mA
Display power factorLag: 0.001-lead: 0.001
Dimension(WxH)DimensionWxHxD(mm)Hole dimensionWxH(mm) 
 144x144x87140×140 