ELC Series reactive power automatic compensation controller
ELC Series reactive power automatic compensation controller
Elcosine Energia based on 3-level topology, is an Active Harmonic Filter (AHF) system designed to eliminate harmonic oscillations and reduce costs consequently. AHF is a versatile solution, easily tailored to deliver power factor improvement, voltage variation control, flicker mitigation and load balancing functionality, and highly improved power quality in networks while reducing harmonic pollution.
- Item NO.: Elcosine Energia
- Order(MOQ): 1
- Payment: T/T,LC
- Market Price: $1500
- Product Origin: Made in India
- Lead Time: 7 days
- Weight: 50kg
ELC series reactive power automatic compensation controller is suitable for the automatic adjustment of capacitor compensation device of low voltage power distribution system (hereinafter referred to as the controller), so that the power factor can reach the user’s predetermined state, improve the utilization efficiency of power transformers, reduce line losses and improve voltage quality of power supply, thereby improving economic and social benefits.
Standard: JB/T 9663-2013
Features
- Calculate switching capacitor capacity with reactive power, high compensation accuracy
- Power factor measurement has high accuracy and wide display range.
- Initial phase preset (software adjusts the same terminal or current signal polarity)
- Two control modes: power factor and reactive power, HMI is easy to operate
- Various control parameters are fully digital adjustable and intuitive to use
- With two working modes: automatic operation and manual operation
- With over-voltage and under-voltage protection
- With data storage protection when power off
- The input impedance of the current signal is ≤ 0.01Ω.
Model and Meaning
| No. | Name | Meaning | |
| 1 | Reactive power compensation controller | ELC | |
| 2 | Enterprise code | 5C: equipped contactor | D5: equipped composite switch |
| 3 | Output Control step | optional step: 4、6、8、 | 10、12 |
| 4 | Rated voltage | AC 220V or 380V |
Technical Parameters
| Normal working and installation conditions | |
| Ambient temperature | -25°C ~ +55°C |
| Relative humidity | Relative humidity % 50% at 40°C ; ≤90% at 20°C |
| Altitude | ≤2000m |
| Environmental conditions | no harmful gas and steam, no conductive or explosive dustz no severe mechanical vibration |
| Power condition | |
| Rated voltage | 220V±20%; THDv≤5%; |
| Rated working current | 0~5A |
| Rated frequency | 50Hz |
| Performance | |
| Control step | 4, 6, 8, 1 0, 12 |
| Measure reactive power | 0-9999 kvar |
| Sensitivity | 60mA |
| Over-voltage protection | 230-260V or 380-500V |
| Output contact capacity | ELC5C static AC 220V 7A 50Hz |
| Output contact capacity | ELCD5 Dynamic DC 12V 12mA |
| Display power factor | Lag: 0.001~lead: 0.001 |
| Protection grade | shell IP40 |
| Switching delay | 1~250s |
| Putting in threshold | Lag: 0.70~lead: 0.70 |
| Cutting off threshold | Lag: 0.70~lead: 0.70 |
| Product | Data Sheet | Catalog |
|---|---|---|
ELC Series reactive power automatic compensation controller | Download | Download |